CIA STARGATE release
CIA-RDP96-00787R000500110001-6
Opens with: Electronics Engineering Department
Warning: text for all documents has not been verified. Errors are possible. Check the original by document ID on CREST.
11 pages, machine transcribed from the CIA’s released scan.
Approved For Release 2002/05/17 : CIA-RDP96-00787R0005001100016RATORY Electronics Engineering Department IN STRICT CONFIDENCE January 11, 1978 WT 79-0027A SG1J DIA Attn: DT-1A 1735 North Lynn Washington, DC 20301 SG1J Dear Enclosed is the outline of the acoustic emission experiment that you requested during our meeting on December 4, 1978. If I can be of any further help, please let me know. Best regards, R.d. Hawke R. S. HAWKE Engineering Research Division Electronics Engineering Department jb Copy to: A. E. Brown H. C. McDonald E. K. Miller A. J. Poggio C. A. Tatro SG11 This is a copy of the letter I sunt The situation hice has improved and I thank you for the lead. Ros IN STRICT CONFIDENCE R000500110001-6 Approved For Release 2002/
? Approved For Ral Jas 200167CC/ HP19:197675000500110001-6 OUTLINE OF ACOUSTIC EMISSION EXPERIMENTS PERFORMED WITH A PERSON REPUTED TO HAVE PARANORMAL METAL BENDING ABILITIES R. S. Hawke Lawrence Livermore Laboratory, University of California Livermore, CA 94550 January 11, 1979 ABSTRACT This outline summarizes the design, use and results of an acoustic emission experiment intended to investigate para- normal metal bending phenomena. The experiment was designed not merely to verify or refute the occurrence of paranormal metal bending, but rather to gain some insight into the phenomena occurring in a test specimen while bending was attempted. Although large amounts of bending were not observed during the experiments, acoustic emission signals typical of single grain or grain boundary fracture with and without evidence of plastic strain-induced emission were recorded during periods of time when there was no contact with the test specimens. These results are consistent with those of Crussard (1) . Further experiments are warranted. IN STRICT CONFIDENCE Approved For Release 2002/05/17 : CIA-RDP96-00787R000500110001-6
Approved For Release 2002/05/17 : CIA-RDP96-00787R000500110001-6 0 I. Introduction IN STRICT CONFIDENCE A. Previous claims : 1. Metal can be paranormally bent without physical contact. 2. Metal seemingly becomes soft and pliable (sub- jective experience of subject) . B. Type of research needed: 1. Determine internal phenomenology. 2. Determine physical cause of phenomenology. 3. Develop and test hypothesis of actualization mechanism. C. Reason acoustic emission (A.E. ) was chosen: 1. Very sensitive. . a. Responds to a single intragranular or inter- granular fracture or grain boundary slip or crystallographic change. b. Good potential for use as a feedback device to subject. c. High sensitivity requires non-contact, hence decreases possibility of deception. 2. Provides continuous record during the event and can be recorded for later analysis. 3. Can distinguish between different types of metal- lurgical phenomenon. 4. A. E. signals are very distinct from all forms of touching, rubbing and other noise. IN STRICT CONFIDENCE Approved For Release 2002/05/17 : CIA-RDP96-00787R000500110001-6
-3- Approved For Release 2002/05/17- CIA-RDP96-00787R000500110001-6 IN STRICT CONFIDENCE II. Experimental design: (Ref. 2) A. Acoustic emission components (See Figure 1) . 1. A. E. Sensor a. Lead Zirconate Titinate (PZT) element. b. Bandpass, DC - 1 MHz, low Q, resonant at 140 KHz. c. Open circuit sensitivity, 4.47 mV/Pa @ 140 kHz; 0.141 mV/Pa @ 1 KHz. d. Shaped to fit and epoxied to bowl of standard stainless steel spoon. 2. Preamplifier a. Gain 60 db. b. Bandpass 1 kHz - 1 MHZ 3. Amplifier a. Gain 35 db. b. Bandpass 1 kHz - 1 MHZ 4. Video tape recorder a. Modified to record positive and negative sig- nals (Standard TV is non-symmetric pulse code) . b. Bandpass 30 Hz - 3MHz. c. A. E. and room conversation recorded on video channel. d. Auxillary audio channel (See Below) . 5. Root mean square (RMS) voltmeter. 6. Pulse counter. 7. Strip chart recorders. a. Record RMS voltmeter and pulse counter outputs. Approved For Release 2002/05/17 : $1/ IN STRICT CONFIDENCE0500110001-6 1 .
Approved For Release 2002/05/17 : CIA-RDP96-00787R000500110001-6 W STRICT CONFIDENCE B. TV video camera and recorder (Figure 2) . 1. Standard System a. Used to record the location of people and objects. b. Used to record the response of the logic probes used in diagnostics. c. Used to monitor the laser beam position which monitors the degree of bending. C. Other diagnostics: 1. Electric field on spoon. a. Logic probe connected to vise and spoon. b. Light emission whenever input signal is greater than 1 V, DC - 1 GHZ. c. Logic probe light output recorded with TV vidicon. d. Background electromagnetic (EM) effects. i. Below logic probe threshold when not touched. ii. Above threshold when touched. 2. Magnetic field near spoon. a. Air core inductor placed beneath spoon handle and connected to logic probe. . b. Coil inductance 30 mH. c. Bandpass 1kHz - 10 MHZ. d. Background EM effects. i. None. 3. AM radio Approved For ReleaseSooRE:CONFIDENCE 00500110001-6
1 . Approved For Release 2002/05/17 : CIA-RDP96-00787R000500110001-6 IN STRICT CONFIDENCE a. Tuned to 1600 kHz at end of band (no broad- cast station) . b. Output connected to logic probe and auxillary audio input to A. E. video recorder. c. Background EM effects. i. None. 4. Laser beam bend detector. a. HeNe laser beam reflected off bottom of spoon bowl and down onto table with target. b. Position of beam on target changes with spoon bending. c. Beam position on target recorded by vidicon TV system. III. Experimental protocol A. Spoon and vise could not be moved during experiment. B. Spoon could be lightly touched by subject for short periods of time but subject was informed that touching obliterated any useful result that might be present while touching occurred and hence was to be minimized if not totally avoided. 1. Logic probe connected to electric field detector provided record of spoon touching. 2. A. E. System provided record of noise if the spoon was rubbed. 3. TV vidicon provided record of hand or finger in proximity of spoon and vise. Approved For Release 2082/05/17. CIA-PPPP IN STRICT CONFIDENCE 00110001-6
.. Approved For Release 2002/05/17 - CIA-RDP96-00787R000500110001-6 IN STRICT CONFIDENCE c. Experimental sessions were about 1 hour long. D. Sessions had subject and 2 or 3 observers present. IV. Experimental results: A. At least 4 clear instances of A. E. events occurred with one subject during one session. 1. Records verified events occurred while spoon and vise were untouched. 2. Sufficient bending to move the reflected laser beam was not observed. a. Normal elastic bending (without A. E. ) prior to plastic deformation (with A.E. ) would have caused an observable displacement of the laser beam. 3. The events were typical of single grain or grain boundary fracture with and without evidence of plastic strain induced emission following. (See Figure 3A and 3B) . 4. No anomalous A. E. events were recorded during dry runs. B. Fewer but similar results were obtained with one other subject. V. Conclusions A. Acoustic emissions were recorded in the presence of a person who claimed the ability to paranormally bend metal. B. Elastic deformation was not observed. c. Observable plastic deformation did not occur. Approved For Released CopME CONFOR EDo &FR000500110001-6
L -7- Approved For Release 2002/05/17 : CIA-RDP96-00787R000500110001-6 IN STRICT CONMDENCY D. Further experiments are warranted. E. Future experiments should be more sensitive to minute bending. F. Other materials and crystalline structures should be investigated. References (1) C. Crussard and J. Bouvaist, Memoires Scientifiques Revue Metallurgie, p. 117, February 1978. (2) The assistance of A. E. Brown and C. A. Tatro through- out the design, implementation and interpretation of the experiments, is greatly appreciated. 2 . Approved For Release 398275'CONFIDENCE 929-PP787R000500110001-6
Approved For Release 2002/05/17 : CIA-RDP96-00787R000500110001-6 AN SIMILI LUMNOSNIC Acoustic emission tape recorder (modified video) Acoustic emission sensor Preamp Amplifier Pulse counter Strip chart recorder RMS voltmeter Strip chart recorder Figure 1 - IN DIRILI CONFIDENCE Approved For Release 2002/05/17 : CIA-RDP96-00787R000500110001-6
Approved For lessFRE/5/CONFIDENCE 7R000500110001-6 Top View Target AM radio Electric field -Magnetic field ) Logic probes Auxiliary audio (AM radio input) Laser spot «- Vise Spoon Amplifier Acoustic emission tape recorder (modified video) Preamp D Acoustic- emission sensor Video camera 0 Microphone Laser Strip chart recorders Table AM radio Magnetic field coil Microphone RMS voltmeter Video recorder Figure 2 Approved For Release 2002/05/17 : CIA-RDP96-00787R000500110001-6 IN STRICT CONFIDENCE Pulse counter
Approved For Release 2002/05/17 : CIA-RDP96-00787R000500110001-6 IN STRICT CONFIDENCE Brittle fracture emission Plastic strain induced emission 50 mV/cm 50 us/cm 20 us/cm IN STRICT Approved For Release 2002/05/17- CIA-EDF96-0078YR000500110001-6 Figure 3A and 3B